Hygienic - multifunction buffer
Hygienic - multifunction buffer KE - KER - KER2
with stainless steel corrugated tube heat exchanger for hygienic hot water heating instantaneously only when tapped
Drinking water heat exchanger made of high quality stainless steel corrugated pipe material number 1.4404 or AISI 316L
integrated stainless steel exchanger with insulation separation (5.8 m2 exchanger surface, 29 liter capacity) anode-free,
hygienic and legionella free,
no control or pump needed for DHW heating,
high tapping rates
Volumes from 500 liters to 10 000 liters.
Buffer Type KE are without solar or additional generator heat exchangers.
Buffer Type KER have a solar heat exchanger in the lower area.
Buffer Type KER2 have a solar heat exchanger in the lower area and an additional heat exchanger in the upper area.
Domestic hot water tanks - glazed
WAMAK SWP - SWP2
Ideal for increasing the efficiency of heat pumps for domestic hot water.
double glazing inside, outside primed
50 mm PU hard foam, firmly foamed
made of high quality steel S235JRG2
produced according to DIN 4753 and Euronorm EN 12897
WAMAK SWP
Hot water storage to heat pumps, type SWP. Internally glazed hot water storage tanks are especially suitable for use with heat pumps. Both tanks and smooth tube heat exchangers are made of high quality steel S235JRG2 according to DIN 4753 and Euronorm EN 12897. The smooth tube heat exchanger is firmly welded in production. The container is glazed inside with a 2-layer glaze.
WAMAK SWP2
Hot water storage to heat pumps, type SWP. Internally glazed hot water storage tanks are especially suitable for use with heat pumps in combination with thermal solar panels. Both tanks and smooth tube heat exchangers are made of high quality steel S235JRG2 according to DIN 4753 and Euronorm EN 12897. The smooth tube heat exchanger is firmly welded in production. The container is glazed inside with a 2-layer glaze.

Buffer tanks

WAMAK P
Buffer tanks, type P. Buffer tanks without heat exchangers with sufficient connections are used in heating, solid fuel and solar plants as well as cogeneration plants. Tanks are made of high quality steel S235JRG2 according to DIN 4753 and Euronorm EN 12897.
WAMAK PR
Buffer storage, type PR. Buffer tanks with a heat exchanger in lower section and with sufficient connections are used in heating, solid fuel and solar plants as well as cogeneration plants. Both tanks and smooth tube heat exchangers are made of high quality steel S235JRG2 according to DIN 4753 and Euronorm EN 12897. The smooth tube heat exchanger is firmly welded in the production.
WAMAK PR2
Buffer storage, type PR2. Buffer tanks with two heat exchangers down / up and with sufficient connections are used in heating, solid fuel and solar plants as well as combined heat and power plants. Both tanks and smooth tube heat exchangers are made of high quality steel S235JRG2 according to DIN 4753 and Euronorm EN 12897. The smooth tube heat exchanger is firmly welded in the production.
Volumes 200 Liter up to 10 000 Liter.
Multifunctional tanks - WAMAQube
Introduction of new hot water storage tanks with multifunctional use. The cylinders are made of composite thermoplastics in rotation and reinforced with high-strength glass fibers. They are factory-fitted with a PUR insulation with a thickness that guarantees a qualification in the energy consumption class A.
The containers can be equipped with various inserts and can be used as one of the options described below
- Stratifications hydraulic separator
- Hygienic hot water instantaneous water heater with exchanger surface up to 7m2,
- Hygienic hot water instantaneous water heater with exchanger surface up to 7m2 with additional solar heat exchanger,

Buffer

Separator

Hygienic

HygienicSolar

Volumes 285 Liter or 480 Liter.
Main advantages are
- Energy efficiency class A li>
- corrosion resistance li>
- high pressure stability li>
- Hygienic heating of warm drinking water through large-surface stainless steel heat exchangers li>
- beautiful, space-saving design li>
- low weight li>
- long-term resistance to external conditions li>
- optimized stratification li>