AIWA EVI H Comfort Outdoor / Indoor
Compact air-water heat pump with or without capacity regulation for indoor or outdoor installation
Compact outside or inside installed air-water heat pump. Versions designated "i" are equipped with an integrated capacity control. Depending on the type of maximum flow temperature of up to 65 ° C. Compact design, integrated control cabinet with control.
Closed cooling circuit with Copeland Scroll compressor and heat exchangers. When capacity control variants with build in frequency inverters. Wide application possibilities of heating and cooling of houses and water heaters. Active cooling is reversible standard possible. Easy installation without complicated wiring and installation of refrigeration. Optimized for low temperature heating systems not only in new construction but also for heating systems with mid temperature flow after renovations.
Frame construction with solid base plate on adjustable feet. Epoxy-coated panel of the base unit. With weather-compensated, digital heat pump control. To control a heating circuit with mixer and one heating circuit without mixer.
Plain text user guidance with function-dependent menu levels, information texts and states in plain text. Diagnostic system with history storage and output state indication. Outdoor temperature sensor, hot gas sensor, liquid refrigerant sensor, heat pump flow temperature sensor and return temperature sensor, as well as source-flow sensor, source return sensor and DHW sensor included.
Build-in condenser pump, backup heating element of 6 kW as well as 3 way switching valve for DHW preparation in packaging.
Optionally available with ModBus module as well WebControl control and monitoring via the Internet.
Compact outside or inside installed air-water heat pump. Versions designated "i" are equipped with an integrated capacity control. Depending on the type of maximum flow temperature of up to 65 ° C. Compact design, integrated control cabinet with control.
Closed cooling circuit with Copeland Scroll compressor and heat exchangers. When capacity control variants with build in frequency inverters. Wide application possibilities of heating and cooling of houses and water heaters. Active cooling is reversible standard possible. Easy installation without complicated wiring and installation of refrigeration. Optimized for low temperature heating systems not only in new construction but also for heating systems with mid temperature flow after renovations.
Frame construction with solid base plate on adjustable feet. Epoxy-coated panel of the base unit. With weather-compensated, digital heat pump control. To control a heating circuit with mixer and one heating circuit without mixer.
Plain text user guidance with function-dependent menu levels, information texts and states in plain text. Diagnostic system with history storage and output state indication. Outdoor temperature sensor, hot gas sensor, liquid refrigerant sensor, heat pump flow temperature sensor and return temperature sensor, as well as source-flow sensor, source return sensor and DHW sensor included.
Build-in condenser pump, backup heating element of 6 kW as well as 3 way switching valve for DHW preparation in packaging.
Optionally available with ModBus module as well WebControl control and monitoring via the Internet.
Build-in condenser pump, backup heating element of 6 kW as well as 3 way switching valve for DHW preparation in packaging.
Heat pump type | AiWa 08 EVI H Out | AiWa 11 EVI H Out | AiWa 14 EVI H Out | AiWa 18 EVI H Out | AiWa 08 EVI H In | AiWa 11 EVI H In | AiWa 14 EVI H In | AiWa 18 EVI H In |
---|---|---|---|---|---|---|---|---|
Article nr. | WA0e1352 | WA0e1353 | WA0e1354 | WA0e1355 | WA0i1352 | WA0i1353 | WA0i1354 | WA0i1355 |
Refrigerant | R410A | R410A | R410A | R410A | R410A | R410A | R410A | R410A |
Heating capacity [ kW ] | ||||||||
A2/W35 | 8.1 | 11.05 | 13.8 | 17.8 | 8.1 | 11.05 | 13.8 | 17.8 |
A7/W35 | 9.45 | 12.89 | 16.1 | 20.77 | 9.45 | 12.89 | 16.1 | 20.77 |
A-2/W35 | 7.5 | 10.23 | 12.77 | 16.47 | 7.5 | 10.23 | 12.77 | 16.47 |
A2/W55 | 8.25 | 11.26 | 14.06 | 18.14 | 8.25 | 11.26 | 14.06 | 18.14 |
Input [ kW ] | ||||||||
A2/W35 | 1.98 | 2.7 | 3.45 | 4.57 | 1.98 | 2.7 | 3.45 | 4.57 |
Performance COP | ||||||||
A2/W35 | 4.1 | 4.1 | 4 | 3.9 | 4.1 | 4.1 | 4 | 3.9 |
Parameter of heat rejection | ||||||||
Maximal flow temperature [ ºC ] | +65°C | +65°C | +65°C | +65°C | +65°C | +65°C | +65°C | +65°C |
Minimal flow temperature [ ºC ] | +12°C | +12°C | +12°C | +12°C | +12°C | +12°C | +12°C | +12°C |
Flow nominal [ m3/h ] | 1.41 | 1.91 | 2.39 | 3.08 | 1.41 | 1.91 | 2.39 | 3.08 |
Pressure drop ( max. ) [ kPa ] | 12 | 12 | 12 | 15 | 12 | 12 | 12 | 15 |
∆T recommended [ K ] | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
Connection port size [ " ] | 1" | 1" | 1.1/4" | 1.1/4" | 1" | 1" | 1.1/4" | 1.1/4" |
Parameter of low potential heat source ( source ) | ||||||||
Minimal source temperature [ ºC ] | -22°C | -22°C | -22°C | -22°C | -22°C | -22°C | -22°C | -22°C |
Maximal source temperature [ ºC ] | +40°C | +40°C | +40°C | +40°C | +40°C | +40°C | +40°C | +40°C |
Flow source nominal [ m3/h ] | 2450 | 3340 | 4140 | 5290 | 2450 | 3340 | 4140 | 5290 |
Pressure drop source ( max. ) [ kPa ] | 0.02 | 0.023 | 0.027 | 0.024 | 0.02 | 0.02 | 0.027 | 0.024 |
∆T recommended source [ K ] | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
Connection port size source [ " ] | 700mm x 700mm | 700mm x 700mm | 700mm x 700mm | 976mm x 976mm | ||||
Parameter of electrical connection and planing | ||||||||
Mains dimension [ mm2 ] | 5x4 | 5x4 | 5x4 | 5x4 | 5x4 | 5x4 | 5x4 | 5x4 |
Voltage [ V ] | 3 x 400 | 3 x 400 | 3 x 400 | 3 x 400 | 3 x 400 | 3 x 400 | 3 x 400 | 3 x 400 |
Safety protection [ A ] | 20 | 20 | 25 | 25 | 20 | 20 | 20 | 25 |
Current - nominal [ A ] | 3.56 | 4.28 | 5.58 | 9.32 | 3.56 | 4.28 | 5.58 | 9.32 |
Current - maximal [ A ] | 6.5 | 9.2 | 10.9 | 16 | 6.5 | 9.2 | 10.9 | 16 |
Current - Start [ A ] | 9.6 | 11.55 | 15.06 | 18.9 | 9.6 | 11.55 | 15.06 | 18.9 |
Softstart | MCI 12 | MCI 12 | MCI 12 | MCI 15 | MCI 12 | MCI 12 | MCI 12 | MCI 15 |
Energy Efficiency Parameters and Performance ErP [ middle region Brussels ] | ||||||||
Energy class | A++ | A++ | A++ | A++ | A++ | A++ | A++ | A++ |
SCOP | 4.01 | 4.05 | 3.98 | 3.90 | 4.01 | 4.05 | 3.98 | 3.90 |
Seasonal energy efficiency η [ % ] | 160 | 162 | 159 | 156 | 160 | 162 | 159 | 156 |
Rated nominal heating capacity P rated [ kW ] | 9 | 13 | 16 | 21 | 9 | 13 | 16 | 21 |
Bivalent point [ ºC ] | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 |
Sound emissions - indoor Lw [ dB(A) ] | -0 | -0 | -0 | -0 | 45 | 46 | 48 | 50 |
Sound emissions - outdoor Lw [ dB(A) ] | 63 | 66 | 68 | 70 | -0 | -0 | -0 | -0 |