Waste Heat Recovery Heat pumps TWW WHR

Heat pump with two power stages for heating and domestic hot water. One short closed refrigerant circuit with a pair of quiet Scroll compressors and robust stainless steel plate heat exchangers. Through the connection kit, the circulation pumps can be easily and quickly connected while externally controlling their variable speed.
Use for waste heat recovery. The new technology of WHR Scroll compressors with a shifted working range to the high-temperature region with a favorable COP efficiency, which can even reach 4.2 ~ 4.5 at a water outlet temperature of 70 ~ 80 ºC and as long as the source temperature is between 30 ºC ~ 40 ºC.
Thermal energy from various industrial or ancillary processes is used as a primary source. Usually in the temperature range between 20° and 50°C. Depending on the quality and chemical composition of the process medium, the heat is extracted either directly in the heat pump or via a pre-wired heat exchanger with intermediate circuit. The heat pump then raises this temperature with high efficiency to a usable temperature for heating or hot water.

Heat pump type: TWW 85 WHR 110 WHR
Product sheet
Article nr. WA002075 WA002077
Heating capacity [ kW ] EN 14511
W10 / W35 (max) 46.1
(23.0 ~ 46.1)
60.7
(30.4 ~ 60.7)
W10 / W35 (min) 23.0
(23.0 ~ 46.1)
30.4
(30.4 ~ 60.7)
W10 / W34 46.4
(23.2 ~ 46.4)
61.1
(30.5 ~ 61.1)
W10 / 55 (max) 40.2
(20.1 ~ 40.2)
53.0
(26.5 ~ 53.0)
W10 / W55 (min) 20.1
(20.1 ~ 40.2)
26.5
(26.5 ~ 53.0)
W10 / W52 42.0 (21.0 ~ 42.0) 55.4 (27.7 ~ 55.4)
Energy Efficiency Parameters and Performance ErP [ middle temperature region ]
Rated nominal heating capacity P rated [ kW ] 46.1 60.7
Energy class A+++ A+++
SCOP 6.59 6.66
Seasonal energy efficiency η [ % ] 263.5 266.5
Bivalent point [ ºC ] -7 -7
Parameter of heat sink
Maximal flow temperature [ ºC ] 85 85
Minimal flow temperature [ ºC ] 45 45
Flow nominal [ m3/h ] [@35/30] 5.53 ~ 11.06 7.28 ~ 14.55
Pressure drop [ kPa ] [@35/30] 20 20
Nominal ∆T [ K ] [@W35°C] 5 5
Nominal ∆T [ K ] [@W55°C] 8 8
Nominal ∆T [ K ] [@W65°C] 10 10
Connection port size [ " ] VIC 2.1/2" VIC 2.1/2"
Parameter of low temperature heat source
Minimal source temperature [ ºC ] -10 -10
Maximal source temperature [ ºC ] 50 50
Flow source nominal [ m3/h ] 5.20 ~ 10.40 6.84 ~ 13.69
Pressure drop source [ kPa ] 20 20
Nominal ∆T source [ K ] 4 4
Connection port size source [ " ] VIC 2.1/2 VIC 2.1/2
Electrical parameters
Voltage [ V ] 3~ 400/50 3~ 400/50
Safety protection [ A ] C40 C80
Current - nominal [ A ] 26.38 34.44
Current - maximal [ A ] 35.40 44.60
Current - Start [ A ] 10.5 12.9
Softstart - -
Sound information
Sound power - indoor Lw [ dB(A) ] 59.4 61.6
Sound power - outdoor Lw [ dB(A) ]
Sound pressure Lp in 1 meter [ dB(A) ] 51.4 53.6
Sound pressure Lp in 5 meter [ dB(A) ] 37.4 39.6
Sound pressure Lp in 10 meter [ dB(A) ] 31.4 33.6
Sound pressure Lp in 15 meter [ dB(A) ] 27.9 30.1